26 www.aeg.com
A
A)
The by-pass screw
• If you change from natural gas G20/
G25 20/25 mbar to liquid gas, fully
tighten the by-pass screw in.
• If you change from liquid gas to natu-
ral gas G20/G25 20/25 mbar, undo the
by-pass screw approximately 1/4 of a
turn.
• If you change from natural gas G20/
G25 20/25 mbar to town gas G130 8
mbar, unscrew approximately 3/4 of a
turn.
• If you change from town gas G130 8
mbar to natural gas G20/G25 20/25
mbar screw approximately 3/4 of a
turn.
• If you change from liquid gas to town
gas G130 8 mbar unscrew approxi-
mately 1 turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• There is a risk of fire when the appli-
ance is in connection with an exten-
sion cable, an adapter or a multiple
connection. Make sure that the
ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable connec-
ted at all times.
8.5 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
8.6 Building In
min.
450 mm
min.
55 mm
30 mm
480 mm
min.
650 mm
560 mm