Connections

! IMPORTANT
Connection with external air intake
The stove has been designed for hermetic installations.
To make the connection with an external air intake, proceed as follows:
step
action
Connect a 50 mm diameter pipe to the combustion air inlet pipe at the back of the stove. Note: the pipe must be no
1
more than 2 m in length.
The air vent must be installed in such a way that it can not be blocked.

Chimney connection

The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
Electrical connection
The plug of the stove power cable must be connected only after installation and assembly has been completed
of the device, and must remain accessible after installation.
To perform the electrical connection, proceed as follows:
step
action
1
Connect the power cord to the back of the stove.
2
Connect the plug of the power cord to the wall socket.


Electric scheme















Use and maintenance manual Infinity Plus 7-9
The connections must be set up by a technician that is qualified and/or authorised by the
Manufacturer.

 











 



 

Page 57

LEGEND:
Safety devices
T1 - Fire door contact
T2 - Ash drawer contact
T3 - Pellet tank contact
T4 - Pellet safety
T5 - Pressure switch
Motors
M1 - Infeed screw gear motor
M2 - Room fan
M3 - Fume exhaust system
M4 - Not present
M5 - Not present
Resistance

R1 - 250watt heaterSonde

Probes
S1 - Flame probe (K)
S2 - External thermostat

S3 - Room probe
S4 - Fume probe (J)
General
G1 - Flow meter
G2 - Extractor revolution

reading encoder





Rev.1 26/03/2018