Make sure that the parallel cable connecting is respected by associating
the same terminal on both generators (red with red and black with black).
2.
Start one engine and then the other one. (please to follow the Start procedure part "6. Starting
the generator.
During parallel mode you can only plug one socket whatever which one, but
no more than one.
Don't disconnect special parallel cables during the parallel running. You can disconnect the
special parallel cables only after stopping the generator. Please to make sure that continuous
output power is no more than 3 kW (13A) and a maximum output power of 3.2kW (14A).
3.
From now you can connect your electrical device.
4.
To stop both generators, please to follow procedure "Stopping the generator".

9. LOW OIL SECURITY

The oil sensor detects the fall in oil level in the crankcase and automatically stops the engine when the oil
level falls below a predetermined level.
When engine has stopped automatically, switch off generator's no-fuse breaker, and check the oil level.
Refill engine oil to the upper level as instructed on page ... and restarts the engine.
NOTE
If the engine doesn't start by usual, consult your nearest Worms Entreprises dealer or service shop.

10. WATTAGE INFORMATION

Some appliances need a ''surge'' of energy when starting. This means that the amount of electrical
power needed to start the appliance may exceed the amount needed to maintain its use. Electrical
appliances and tools normally come with a label indicating voltage, cycles/Hz, amperage (amps) and
electrical power needed to run the appliance or tool. Check with your nearest dealer or service center
with questions regarding power surge of certain appliances or power tools.
Electrical loads such as incandescent lamps and hot plates require the same wattage to start as is
needed to maintain use.
Loads such as fluorescent lamps require 1.2 to 2 times the indicated wattage during start-up. GB 38
Loads for mercury lamps require 2 to 3 times the indicated wattage during start-up.
42