The overload indicator light may come on for a few seconds at first when using electric devices that
require a large starting current, such as a compressor or a submergible pump. However, this is not a
malfunction. (FIG. MU-ACC-6)
4.5. AC PILOT LIGHT
The AC pilot light comes on when the engine starts and produces power. (FIG. MU-ACC-7)
4.6. USB CHARGER
This plug allow to charge portable electrical devices with a low power consumption (phone, tablet,...)
5 volts, 1 ampere. (FIG. MU-ACC-8)
4.7. ECONOMY CONTROL SWITCH
When the economy control switch is turned to "OFF", the engine runs at the rated r/min (4500 r/min)
regardless of whether is a load connected or not. (FIG. MU-ACC-10)
When the economy control switch is turned to "ON" the economy control unit controls the engine
speed according to the connected load. The results are better fuel consumption and less noise.
(FIG. MU-ACC-11)
The economy control switch must be turned to "OFF" when using electric devices that require a large
starting current, such as a compressor of a submergible pump.
4.8. FUEL TANK CAP
Remove the fuel tank cap by turning it counterclockwise. (FIG. MU-ACC-13)
4.9. FUEL TANK CAP AIR VENT KNOB
The fuel tank cap is provided with an air vent knob to stop fuel flow.
When the engine is not in use, turn the air vent knob to "OFF" to stop fuel flow. . (FIG. MU-ACC-14)
During operating, the air vent knob must be turned to "ON". This will allow fuel to flow to the
carburetor and the engine to run. (FIG. MU-ACC-15)
4.10. EARTH (GROUND) TERMINAL
Terminal for grounding the generator. (FIG. MU-ACC-16)
4.11. SOCKET 230 V
Alternative current is provided by this socket. Use a tree map type with earth socket. (FIG. MU-ACC-39)
4.12. PARALLEL TERMINALS
Those both terminals are used to connect specific cable in order to make a two ACCESS 2000i
coupling. The parallel mode must be done with two ACCESS 2000i and the specific parallel cables.
The nominal rated output in parallel running is 3,0 kW and the rated current is 25.0 A. The maximum
output is 3.2 kW. (FIG. MU-ACC-12)