• the new appliance, before being considered seasoned has to be subject to many start cycles to allow all materials and paints to
complete the various elastic stresses;
• in detail, initially it is possible to remark the emission of smells typical of metals subject to great thermal stress, as well as of wet
paint. This paint, although during the manufacture it is backed at 250 °C for some hours, must exceed many times and for a given
period of time the temperature of 350 °C before becoming completely embedded in the metallic surfaces.
Therefore, it is extremely relevant to take these easy steps during the lighting:
1. Make sure that a strong air change is assured in the room where the appliance is installed.
2. During the first starts, do not load excessively the combustion chamber (about half the quantity indicated in the instructions manual)
and keep the product continuously ON for at least 6-10 hours with the registers less open than the value indicated in the instructions
manual.
3. Repeat this operation for at least 4-5 or more times, according to your possibilities.
4. Then load more and more fuel (following in any case the provisions contained in the installation booklet concerning maximum load)
and, if possible, keep the lighting periods long avoiding, at least in this initial phase, short ON/OFF cycles.
5. During the first starts, no object should be leaned on the appliance and in detail on enameled surfaces. Enameled surfaces
must not be touched during heating.
6. Once the «break-in» has been completed, it is possible to use the product as the motor of a car, avoiding abrupt heating with
excessive loads.
To light the fire, it is suggested to use small wood pieces together with paper or other traded lighting means.
It is FORBIDDEN to use any liquid substance as for ex. alcohol, gasoline, oil and similar.
The openings for air (primary and secondary) must be opened together (you must open the eventual Ignition control, and butterfly valve
placed on the pipe of smokes exhaust). When the wood starts burning, you may load other fuels and adjust the air for combustion
according to the instructions on paragraph TECHNICAL DESCRIPTION.
Please always be present during this phase.
Never overload the appliance (see the technical table - max quantity of fuel that can be loaded / hourly consumption). Too much fuel and
too much air for combustion can cause overheating and therefore damage the appliance. The warranty does not cover the damages
due to overheating of the equipment.
Never switch on the device when there are combustible gases in the room.

12.1. LOW EMISSION fire lighting

Smokeless combustion is a way of lighting a fire able to significantly reduce the emission of harmful substances. The wood burns gradually
from the top downwards, so combustion is slower and more controlled. Burnt gases pass through the high temperatures of the flame and
therefore burn almost completely. A load will last from 6 to 8 hours.
Place the logs in the hearth a certain distance apart as shown in the
at the top, or vertically in the case of tall narrow combustion chambers. Place the fire starter module on top of the pile, arranging the first
logs in the module at right angles to the pile of wood.
Fire STARTER MODULE. This fire starter module replaces a paper or cardboard starter.
Prepare four logs, 20 cm long with a cross section of 3 cm by 3 cm
pile of wood at right angles, with the fire lighter (wax impregnated wood fibre for example) in the middle. The fire can be lit with a match. If
you want, you can use thinner pieces of wood. In this case, you will need a larger quantity.
Keep the flue gas exhaust valve and combustion air regulator open.
After lighting the fire, leave the combustion air regulator open in the position shown in according to the instructions on paragraph
TECHNICAL DESCRIPTION
IMPORTANT:
do not add further wood between one complete load and the next;
do not suffocate the fire by closing the air intakes;
regular cleaning by a chimney sweep reduces fine particle emissions.
These instructions are backed by ENERGIA Legno SVIZZERA

13. NORMAL OPERATION

After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous stresses and
deformations (according to the instructions on paragraph TECHNICAL DESCRIPTION). You should always use the product with the
door closed in order to avoid damages due to overheating (forge effect). The inobservance of this rule makes the warranty expire.
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the fuel or for removing
the ashes, while during the operation and the rest, the door of the hearth must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is allowed under supervision.
IMPORTANT: For safety reasons the door of the hearth can be opened only for the loading of the fuel. The hearth door must
always remain closed during operation or rest.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be opened
according to the calorific need. The best combustion (with minimum emissions) is reached when, by loading the wood, most part of the air
for combustion flows through the secondary air register.
Never overload the appliance (see the hourly wood load in the table here below). Too much fuel and too much air for the combustion may
22
Picture 8 at page
Picture 8 at page
FUEL
Wood
45. Arrange the largest at the bottom and the smallest
45. Cross the four logs and place them on top of the
Primary AIR
CLOSED
www.energia-legno.ch
WANDA - WANDA CLASSIC
Aria SECONDARIA
1/2 OPEN