Service And Repairs - Hitachi EC 10SB Manuel D'utilisation Et Consignes De Sécurité

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
WARNING:
Disconnect the compressor from the
power source and remove the
compressed air from the air tank
before performing the maintenance
operations.
1. Cleaning the intake filter
Remove the intake filter (Refer to Fig. 1.) every 50
hours or once a week and clean the inside of the
intake filter and the filter element with compressed air.
(Fig. 7)
Use a phillips screwdriver to disassemble intake filter.
WARNING:
Never clean filter element with a
flammable liquid or solvent.
Fig. 7
NOTE:
Replace the filter element when it becomes dirty.
2. Draining tank
Drain tank daily or after 4 hours of use. Open drain
fitting and tilt compressor to empty accumulated
water. (Fig. 6).
3. Oil change-oil topping off
(1) Within the first 50 hours of operation, completely
replace the oil of the pumping element. Unfasten
the oil drain cap on the casing cover, drain all the
oil, and screw the cap back on (Fig. 8).
Drain cap
Fig. 8
Filter element
Intake filter
— 11 —
Pour oil into the hole of the dipstick.
To the level indicated on the dipstick (Fig. 4).
For oil replacement, follow the table below.
OIL TYPE
SAE 5W50 SYNTHETIC OIL (–20°+120°F)
For both summer and winter use
SAE 10W40 MULTI-GRADED OIL (+50°+120°F)
For warm weather use only
(2) Check the oil level of the pumping element every
50 hours or once a week.
(3) Change the oil every 300 working hours or every 6
months.

SERVICE AND REPAIRS

All quality compressors will eventually require servicing
or replacement of parts because of wear from normal use.
To assure that only authorized replacement parts will be
used, all service and repairs must be performed by a
HITACHI AUTHORIZED SERVICE CENTER, ONLY.
NOTE:
Specifications are subject to change without any
obligation on the part of the HITACHI.
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ec 10sc

Table des Matières