Tank
4.
About the thermal protector
The thermal protector operates to stop the motor when a
problem such as a motor overload, etc. occurs.
If the motor should stop during operation, proceed as
follows.
(1) Place the knob of the pressure switch in the "OFF"
positon and disconnect the plug from the receptacle
(Fig. 2).
(2) Check for the following possible causes fi rst: lack
of proper ventilation, or an outside-air or room
temperature that is too high.
2.
Maintenance chart:
PROCEDURE
Drain condensation in air tank
Inspect guards/shrouds
Check for unusual noise/vibration
Check for air leaks
Clean exterior of compressor
Check safety valve

SERVICE AND REPAIRS

All quality compressors will eventually require servicing or
replacement of parts because of wear and tear from normal
use. To assure that only genuine replacement parts will be
used, all service and repairs must be performed by a HITACHI
AUTHORIZED SERVICE CENTER, only.
NOTE: Specifi cations are subject to change without any
obligation on the part of the HITACHI.
000Book̲EC710S.indb 12
000Book̲EC710S.indb 12
Drain cock
Open
Fig. 5
MAINTENANCE CHART
AFTER USE
×
(3) If the extension cord does not conform to the
specifi cations given on page 7 replace with an
extension cord such as that shown on page 7. If the
capacity of the power supply is insuffi cient, increase
the power supply capacity to remove the cause of a
fl ow of excessive current (over-current).
(4) Wait approximately 30 minutes.
(5) Start up. If the motor still stops during operation,
please contact the service center.

MAINTENANCE

WARNING
: Disconnect
the power source and remove the
compressed air from the air tank
before performing the maintenance
operations. Allow the compressor
to
cool
maintenance operations.
1.
Draining tank
Drain tank daily or after 4 hours of use. Open drain cock
and tilt compressor to empty accumulated water (Refer
to Fig. 5). Tank pressure should be below 10 psi when
draining the tank.
DAILY
×
×
×
×
×
— 12 —
the
compressor
from
before
performing
the
WEEKLY
×
2016/03/18 12:20:36
2016/03/18 12:20:36