Lubricant
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Viscosity / Room Temperature diagram
mm
2
/s = cSt
The used oil must be placed in a suitable container and disposed of in special centres.
It absolutely should not be discarded into the environment.
Check the oil level and top up if necessary
Using the oil dipstick pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in Fig. 14 chapter 11.
The quantity required is ~ 2 litres.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
25
Fig. 3