Hitachi UC 18YG Instructions De Sécurité Et Mode D'emploi page 10

Masquer les pouces Voir aussi pour UC 18YG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Rechargeable batteries
EB712S, EB7S, FEB7S, EB714S,
EB7B, EB912S, EB9S, FEB9S,
EB914, EB914S, EB9B, EB924,
EB1212S, EB12S, FEB12S,
EB1214L, EB1214S, EB12B,
EB1220BL, EB1224, EB1412S,
EB1414, EB1414S, EB14B,
EB1424, EB1812S, EB1814SL,
EB1820, EB1820L, EB1824L
Regarding recharging time
Table 3 shows the recharging time required according to the type of battery.
Battery
voltage (V)
EB712S, EB7S,
7.2
FEB7S, EB714S
EB912S, EB9S, FEB9S,
9.6
EB914, EB914S
EB1212S, EB12S,
12
FEB12S, EB1214L,
EB1214S
EB1412S, EB1414,
14.4
EB1414S
18
EB1812S, EB1814SL
NOTE: The recharging time may vary according to the ambient temperature and the
power supply voltage.
4. Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by pulling on the cord.
Make sure to grasp the plug when removing from receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the battery from the battery charger.
10
Temperature at which the battery can be recharged
32°F — 104°F (0°C — 40°C)
Table 3 Recharging time (approx. min.) at 20°C
1.2–1.4 Ah
30 min.
Table 2
Battery capacity (Ah)
2.0 Ah
EB7B
EB9B
EB12B,
EB1220BL
EB14B
EB1820,
EB1820L
2.4 Ah
–––
EB924
50 min. EB1224
EB1424
EB1824L
–––
60 min.

Publicité

Table des Matières
loading

Table des Matières