Thank you for buying this product. Our company is sure that you will be more
than satisfied with the performance of the product. This product is supplied
with a "WARNINGS" leaflet and an "INSTRUCTION MANUAL". These
should both be read carefully as they provide important information about
safety, installation, operation and maintenance. This product complies with
recognised technical standards and safety regulations. We declare that this
product is in conformity with the following European Directives: 89/336/CEE,
73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL OUTLINE

Compact electromechanical barrier suitable for limiting private areas, park-
ings, access areas for vehicles only. Available for passageways from 3 to 5
metres. Adjustable electromechanical limit devices ensuring a correct stop
position for the boom. In case of intensive use, a thermal sensor activates
the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side fitting. However, when
necessary, the opening direction can be reversed by means of simple
operations.
The CBO mod. foundation base (on request) makes barrier installation
easier.
Appropriate fittings make it easy to install accessories without needing to
drill any holes.
The LEO-MV control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of UNIPRO. The Control unit completely sup-
ports the EELINK protocol, including the programmer self-supply from the
control unit.
Its main characteristics are:
-
Closing / opening limit-switch inputs
-
Separate inputs for safety devices
-
Clock input
-
Serial protocol connection input
-
Incorporated radio receiver
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of
pre-wired jumpers to facilitate the installer's work.
The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use, remove their respective jumpers.

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
16
- MOOVI 30S-30RMM-50RMM Ver. 07
INSTALLATION MANUAL
shearing, according to and in compliance with the applicable directives
and technical standards.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
3) TECHNICAL SPECIFICATIONS
MOOVI 30S
Power supply: ......................................................... 230Va.c.±10% 50Hz (*)
Absorbed power: ................................................................................ 300W
Motor: ............................................................................. 2800 min
Capacitor: ......................................25µF 450V (230V): 100µF 250V (110V)
Absorption: .............................................................................. 0.8 A - 1.6 A
Insulation class: ......................................................................................... F
Ventilation intervention temperature: .................................110 °C (winding)
Circuit-breaking intervention temperature:................ 130 °C (self-resetting)
Reduction gear lubrication:............................................. Permanent grease
Max torque:.........................................................................................72Nm
Minimum opening time:........................................................................ 1.5 s
Boom (aluminium) length:...............................................................3m max.
Impact reaction: ..................................Obstacle detection device (Encoder)
Limit devices:..................................... Electric, incorporated and adjustable
Manual manoeuvre:......................................................... Quick key release
Maximum no. manoeuvres in 24h (peak):............................................ 3000
Working temperature: ......................................................... -10°C to +55 C°
Degree of protection: ............................................................................ IP24
Operator weight (without boom): ........................................356N (~35.6 kg)
Dimensions:.................................................................................. See fig. 1
(*) Special supply voltages available on request.
MOOVI 30 RMM - MOOVI 50 RMM
Power supply: ......................................................... 230Va.c.±10% 50Hz (*)
Absorbed power: ................................................................................ 300W
Motor: ............................................................................ 1400 min
Capacitor: ..........................................8µF 450V (230V) :32µF 250V (110V)
Absorption: ................................................................................0.8 A :1.6 A
Insulation class: ......................................................................................... F
Ventilation intervention temperature: ..................................110°C (winding)
Circuit-breaker intervention temperature: .................. 130°C (self-resetting)
Reduction gear lubrication:............................................. Permanent grease
Max torque:....................................... MOOVI-30 85Nm: MOOVI-50 250Nm
Opening time: ................................................ MOOVI-30 4s : MOOVI-50 8s
(Aluminium) bar length: .............. MOOVI-30 3m max : MOOVI-50 5m max.
Impact reaction: ..................................Obstacle detection device (Encoder)
Limiting devices: ................................ Electric, incorporated and adjustable
Manual manoeuvre:......................................................... Quick key release
No. manoeuvres in 24 hour:.................1200 (MOOVI-30) :600 (MOOVI-50)
Working temperature: ........................................................... -10°C ÷ +55°C
Degree of protection: ............................................................................ IP24
Actuator weight (without bar):.............................................356N (~35.6 kg)
Dimensions:................................................................................... See fig.1
(*) Special power voltages available on request.
LEO-MV CONTROL PANEL
Power supply: .............................................................230Va.c.±10% 50Hz
Mains/low voltage insulation: ......................................... > 2MOhm 500Vdc
Dielectric strength: ....................... mains/low voltage 3750Vac for 1 minute
Maximum motor power: ..................................................................... 750W
Supply to accessories: ..................................... 24Vac (1A max absorption)
Gate-open warning light: ................................................ 230Va.c. 3W max
Blinker: .......................................................................... 230Va.c. 40W max
Dimensions: ............................................................................see figure 17
Fuses: .....................................................................................see figure 18
4) OPTIONAL ACCESSORIES (Fig.15)
-
CBO. Foundation base
-
MOOVI PRM. Antishearing Kit