Roof Exhaust With Traditional Fireplace - Palazzetti ECOFIRE MELITA Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.6 Roof exhaust with traditional
fireplace
The chimney for the evacuation of flue gases
must be made by qualified personnel in compli-
ance with standards UNI 10683- EN 1856-1-2- EN
1857-EN 1443- EN 13384-1-3- EN 12391-1 both in
terms of the dimensions and the materials used
in its construction.
The evacuation of flue gases via a traditional
chimney (Fig. 19) can be done as long as you are
sure of the state of maintenance of the chimney.
In the case of an old chimney, it is advisable to
renew it using ducting.
The flue gas exhaust must be on the roof.
1
2
1) Wind-proof cowl
2) Seal
3) Inspect
56
If the chimney has a larger section, it
must be "intubated" with a suitably in-
sulated steel pipe (with diameter suita-
ble for the route) (Fig. 20).
Make sure that the connection to the brickwork
chimney is properly sealed.
In case of pipes that pass through
wooden roofs or walls, it is recommend-
ed to use special certified ducting kits
commonly available on the market.
3
Fig. 19
1) Non-combustible material
2) Steel piping
3) Closing panel
1
2
3
004778851 - 19/10/2021
Fig. 20