Handling of the cage tension spring clamps
Prepare the connecting cable. The cable end for the connection B+ (small cage
tension spring clamp) must be stripped 8–9 mm. The cable ends for the battery
connections (large cage tension spring clamps) must be stripped 11-12 mm.
Cable end sleeves are not required.
The tension spring clamp can be opened with the help of a suitable flat screw-
driver.
To do so, insert the flat screwdriver into the lower, square opening (fig. 3) and
open the tension spring clamp (fig. 4). The clamping element of the spring in
the upper, round opening opens.
Insert the cable into the cage tension spring clamp up to the isolation (upper,
round opening, fig. 4) and pull out the flat screwdriver (fig. 5). The tension
spring clamp closes again and the cable is securely clamped.
Repeat the procedure for all connections:
B+, batt. I +, batt. II +, batt. I -, batt. II -.
Make sure that the cable ends sit firmly in the cage tension spring clamps!