ELECTRICAL REQUIREMENTS cont.
POWER SUPPLY CORD
Wiring Requirements
For model ESA415M
• 115-volt (103.5 minimum to 126.5 maximum)
• 15-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
For model ESA418M
• 230/208 volt (187 min. to 253 max.)
• 15-amp time-delay fuse or circuit breaker
• Use on single outlet circuit only.
For model ESA424K
• 230/208 volt (187 minimum to 253 maximum)
• 20-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
RECOMMENDED GROUNDING METHOD
This air conditioner must be grounded. This air conditioner is equipped with a power supply
cord that has a 3 prong grounding plug. The power supply cord must be plugged into a mating,
grounded 3 prong outlet, and grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to contact a qualified electrician
and ensure that a properly grounded 3 prong outlet is installed.
POWER SUPPLY CORD
NOTE: Your air conditioner's plug may differ slightly in appearance
from the one shown.
A. Reset button
B. Test button
This room air conditioner is equipped with an a leakage current detection interrupter ( LCDI)
power supply cord required by UL. This power supply cord contains a current detection device.
If the power supply cord is crushed, this device will detect current leakage and power will be
disconnected from the air conditioner. If this power supply cord is damaged, it cannot be
repaired and must be replaced with a cord from the product manufacturer. If the power supply
cord is damaged call Haier Customer Service: 1-877-337-3639.
PAGE 8
(See Fig.1)
(See Fig.1)
(See Fig.2)
INSTALLATION REQUIREMENTS
Fig. 1
ESA415M
ESA415
ESA418M
115V
15 Amp
ESA415
ESA418
ESA424K
115V
230V
15 Amp
15 Amp
A
Fig. 2
B
ESA415
ESA418
115V
230V
15 Amp
15 Amp
ESA418
ESA424
230V
230V
15 Amp
20 Amp
ESA424
230V
20 Amp