Safety Instructions; Commissioning - Schneider Airsystems SEM 255-10-50 W Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
2.3

Safety instructions

WARNING
Uncontrolled movement of compressed
air hose when quick-action coupling is
opened!
Hold the compressed air hose tightly!
WARNING
Burn hazard on the motor, unit, check
valve, connecting hose/pressure pipe
and from hot oil!
Wear safety gloves!
WARNING
Explosion hazard!
Do not use in potentially explosive areas.
Do not suck in any combustible, corrosive
or poisonous gases!
Do not exceed the max. permitted final
compression pressure.
WARNING
Hearing damage from noise during op-
eration!
Wear ear protection!
WARNING
Damage to the connexion cable!
Protect it from sharp edges, oil and heat!
Grasp the plug and unplug it from the
power outlet!
• Be calm and focused and ensure proper
operation.
• Protect yourself and other persons, ani-
mals, property, and the environment by
taking the necessary protective measures
and being trained in use of the devices to
prevent harm to your health, property
damage,
financial
harm or risk of accident.
• Repairs may be carried out only by
Schneider Druckluft GmbH or its approved
service partners.
loss,
environmental
• Observe the Instruction Manual for ves-
sels!
• Prohibited: Manipulations, use for pur-
posed other than those intended; tempo-
rary repairs; compressing other energy
sources; removing or damaging safety
equipment; use in case of leaks or mal-
functions; not using original spare parts;
exceeding the specified permitted final
compression pressure; working without
safety equipment; transporting the unit,
maintaining it, repairing it or leaving it un-
supervised while pressurised; using other/
incorrect lubricants; smoking; open flame;
removing stickers.
2.4

Commissioning

Observe the safety instructions!
2.4.1 Transport
• Check the handle for secure fit.
• Vessel depressurised.
• In the vehicle: transport the compressor in
an upright position, secure and protect it.
2.4.2 Conditions at the installa-
tion location
• Rooms: as dust-free as possible, dry, well
ventilated.
• Surface: level.
2.4.3 Before first use
1. Carry out a visual inspection.
2. Check the electrical connection.
3. Check the oil level (see Chap. 2.6.6).
2.4.4 Electrical connection
• The mains voltage must match that speci-
fied on the rating plate.
• Electric protection according to technical
data.
• Observe VDE regulations 0100 and 0105.
When using extension cords: cable cross-
section:
min.
length:10 m.
2.4.5 Filling the mist oiler
For compressors with mist oiler:
1. Depressurise the compressor/vessel.
2. Unplug the power plug.
3. Unscrew the oil tank from the mist oiler.
(Figure 3a)
Use suitable oil (Art. No. B770000)!
SEM
2.5 mm²;
max.
GB
cable
II/9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

A 333 001A343001

Table des Matières