4. CONFIGURATION OF THE LOCK FOR LEFT HAND OR RIGHT HAND OPENING
If needed, you can reverse the unlocking direction (fig. 3a-3b)
1 - Press the button "C" to reset the mechanism.
2 - Remove the central plate of the box by previously unscrewing the 2 screws (mark Z fig 3a).
3 - With small tweezers, remove the pin and place it on the opposite direction (the pin must enter the lower part, to
succeed in this operation place the 2 holes horizontally. An incorrectly placed pin prevents the correct closure of the
central plate) (fig. 3b)
(1) Position of the pin for doors which open on the right side. (2) Position of the pin for doors which open on the left side
d. Put the central plate back in position.
The internal button always remains unblocked and turns freely to open or close the lock.
IMPORTANT : Before installing the lock, make sure the bolt in the internal block is in the right position.
If it is not the case: (fig. 4a)
a – Lay the internal block on a flat surface, the 4 rear screws visible.
b – Remove the 4 screws and the plate.
c – Remove the bolt and reverse it (on the left side or on the right side, the drive sheave down)
d – Place the 4 washers on the "nut" parts
e – Screw the plate
(fig. 4b) Right hand assembly
5. POSITIONING THE LOCK
IMPORTANT : Determine the strike to use (flush-mounted or surface-mounted) and mark its position on the frame
before drilling the door.
CAUTION: The bolt is 35 mm taller regarding the side of the lock.
Present the internal block with the handle in vertical position and hold it on the door with an end of the bolt aligned with
the frame where the strike will be installed (see step 7).
Mark the position of the upper mounting hole using the template at the back of 1st page and mark the position of the
lower mounting hole and the hole for the square.
Drill 7 mm holes for the attachment screws and one 9.5 mm hole for the square.
6. FIXING THE LOCK
IMPORTANT : Do not close the door before BEING SURE the code works properly.
The square is planned for 35 to 65 mm thick door.
For lower than 50 mm thick doors, separate a size of 12 mm at the end of the square.
Cut the end of the attachment screws according to the thickness of the door so that with the flanges the screws hold the
lock with three threads
CAUTION: lThe lower attachment screw is longer than the upper screw.
Hold the lock into position, the rear face and the neoprene flanges on the door with the square into
position. Screw all the elements starting by the upper screw.
7. INSTALLING THE STRIKE
First, choose the relevant type of strike for your door and then place the strike on the frame so that it is aligned with the
bolt and mark the corresponding holes.
If you use the surface-mounted strike, only screw it (fig. 7a). Use the supplied parts if necessary.