9.3 DC CURRENT
range
600 µA
6 mA
60 mA
600 mA
15 A
Overload protection: F0.8 A/700 V fuse, F15 A/700 V fuse
Continuous testing maximum steady-state current of 1 A
9.4 AC CURRENT
range
6 mA
60 mA
600 mA
15 A
AC true RMS
Frequency range: 40 Hz-2 kHz
Overload protection: F0.8 A/700 V fuse, F15 A/700 V fuse
Continuous testing maximum steady-state current of 1 A
9.5 RESISTANCE
range
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ
Overload protection: 700 V DC or AC rms
V. 02 – 29/01/2020
DVM903
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
resolution
0.1 µA
1 µA
10 µA
100 µA
10 mA
Do not measure circuits that may contain voltages
> 700 VDC or > 700 VAC
resolution
1 µA
10 µA
100 µA
10 mA
Do not conduct resistance measurements on live
resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
accuracy
± (1.2 % + 2)
± (2.0 % + 3)
accuracy
± (1.5 % + 3)
± (2.5 % + 5)
circuits
accuracy
± (1.0 % + 3)
± (1.0 % + 2)
± (1.5 % + 3)
10