Connection With Natural Gas H G20; Checking Primary Air To The Main Burners And Pilot Nozzles; Burners" Technical Data Table; Rules For Converting And Installing For Other Types Of Gas - Lotus TP-78G Instructions Pour L'installation Et L'emploi

Cuisinieres a gaz, avec plaque rougeoyante usage professionnel
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Connection with natural gas H G20

The connection pressure for natural gas is 20 mbar.
Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.

CHECKING PRIMARY AIR TO THE MAIN BURNERS AND PILOT NOZZLES

All the burners are fitted with an air regulator by means of which the primary air can be varied thanks to an adjustable
bush that can be locked with a screw. In the "Burner Technical Data" table you will find the approximate values for the
"h" parameter (primary air). The flow of primary air must be regulated so there is no detachment of the flame when the
burner is cold or a return of the flame when the burner is hot.
The pilot air is regulated when the appliance is tested and inspected for the gas it is set for.
If you are going to change to a different type of gas, regulate the air by means of the adjusting bush until the flame stops
sputtering and becomes an intense blue colour.
TP Burner max 12 kW - min. 7 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Open ring burner max 3,5 kW- min. 1,15 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h= mm
Open ring burner max 5,5 kW- min. 1,55 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h= mm
Open ring burner max 7,5 kW- min. 2,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h= mm
Oven burner max 7,3 KW- min. 2,2 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h= mm
Oven burner max 11 KW– min. 3,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h= mm

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).
GB
IT

"BURNERS" TECHNICAL DATA TABLE

12.8 kWh/KG
G30
BUTANE
30 mbar
IE
CH
12.8 kWh/KG
G31
PROPANE
37 mbar
165
165
130
130
19
19
0,937 kg/h
0,937 kg/h
90
90
50
50
20
20
kg/h 0,276
kg/h 0,272
open
open
115
115
60
60
20
20
kg/h 0,434
kg/h 0,427
open
open
135
135
75
75
20
20
kg/h 0,591
kg/h 0,582
open
open
145
145
75
75
1x19
1x19
kg/h 0,576
kg/h 0,567
12
12
175
175
100
100
1x19
1x19
kg/h 0,867
kg/h 0,855
13
13
45
3
9.45 kWh/m
st.
G20
NATURAL GAS H
20 mbar
260
130
27
3
1,27 m
st./h
145
adjustable
35
3
m
st./h 0,370
open
175
adjustable
35
3
m
st./h 0,582
20
205
adjustable
35
3
m
st./h 0,794
20
205
adjustable
1x27
3
m
st./h 0,772
12
270
adjustable
1x27
3
m
st./h 1.164
13