English
Important Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one
of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not avoided,
will result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to personal
injury.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition. Replace missing
or damaged safety labels.
California Proposition 65 Warning
This product contains chemicals known
to the State of California to cause cancer or birth
defects or other reproductive harm.
1.
Know the pump application, limitations, and potential
hazards.
Risk of explosion. Do not ground to a
gas supply line. Pump water only with this pump.
Failure to follow this warning can result in personal
injury and/or property damage.
Risk of flooding. Can cause personal
injury and/or property damage. If a flexible discharge
hose is used, make sure pump is secured in sump to
prevent movement. Failure to secure pump may allow
pump movement, switch interference and prevent
pump from starting or stopping.
2.
Make certain power source conforms to requirements
of your equipment.
3.
Disconnect power before servicing.
4.
Release all pressure within system before servicing
any component.
5.
Drain all water from system before servicing.
6.
Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
7.
Check hoses for weak or worn condition before each
use, making certain all connections are secure.
8.
Periodically inspect pump and system components.
Keep sump, pump and system free of debris and
foreign objects. Perform routine maintenance as
required.
9.
Provide means of pressure relief on pumps whose
discharge line can be shut-off or obstructed.
10. Personal Safety:
A. Wear safety glasses at all times when working
with pumps.
B. Keep work area clean, uncluttered and properly
lighted. Replace all unused tools and equipment.
For parts or assistance, call Flotec Customer Service at
C. Keep visitors at a safe distance from the work
area.
D. Make workshop child-proof – with padlocks,
master switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all
electrical and safety codes, as well as most recent
National Electrical Code (NEC) and Occupational
Safety and Health Act (OSHA).
Risk of sudden starts. Can cause
electrical shock and personal injury. Pump motor is
equipped with an automatic resetting thermal protector
and may restart unexpectedly.
12.
Risk of electric shock. Can shock,
burn or kill. This equipment is only for use on 115
volt (single phase) and is equipped with an
approved 3-conductor cord and 3-prong, grounding-
type plug. Be certain that it is connected to properly
grounded, grounding-type receptacle. Where a
2-prong wall receptacle is encountered, it must be
replaced with properly grounded 3-prong receptacle
installed in accordance with the National Electrical
Code and local codes and ordinances.
13. All wiring should be performed by a qualified
electrician.
14. Protect electrical cord from sharp objects, hot
surfaces, oil, and chemicals. Avoid kinking
cord. Replace or repair damaged or worn cords
immediately.
15. Use wire of adequate size to minimize voltage drop
at motor. Refer to most recent National Electrical
Code.
16. Do not touch an operating motor. Modern motors are
designed to operate at high temperatures.
17. Do not use in water where fish are present.
Description
This Submersible Utility Pump is designed for draining
water from basement floors, stock tanks, window wells,
boats, flat roofs and cisterns. Unit is equipped with a
3-prong grounding-type power cord. PSC motor is oil
filled and sealed for cooler operation. Ball bearings on
the motor shaft never need lubrication. Automatic reset
thermal protection.
Pump water only with this pump.
NOTICE This unit is not designed as a waterfall or
fountain pump, or for applications involving salt water
or brine! Use with waterfalls, fountains, salt water or
brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
Do not use this pump in water with fish present. If any
oil leaks out of the motor it can kill fish.
Specifications
Power supply required...............................115V, 60 HZ.
Liquid Temp. Range.............................Max. 77°F (25°C)
Operation Position..............................................Vertical
Individual Branch Circuit Required ....................15 Amp
Operating Depth
Beginning min..........................1/2"
(water level)
Ending max.............................3/16"
Discharge..............................................1" NPT (25 mm)