5.3. Wiring external supply

A terminal is present in the product to connect an external supply in order to:
- Use the Class C LoRaWAN (mandatory for this mode)
- Improve the autonomy of the product
- Send more frames more regularly.
Connect the power cable to the "+" terminal block (V +) with a power supply between 4.5 V and 6.5 V and connect the earth to the "-"
FR
(GND).
EN
5V + -
V+
GND
1 2 3 4
N.B .: To power the product via an external power supply it is nec-
essary to disconnect a probe in order to pass the cable of the power
supply in the cable gland.
N.B: It is not necessary to disconnect the battery when the external
power supply is connected. For the Class C it is even advisable to
keep it to benefit from the "back-up" mode in case of power failures.