TEMP V4 IP68 LoRaWAN 863-870 - Guide utilisateur / User guide version V3.1.1
2.4.3 Transmission on threshold overpassed
FR
EN
Value <(high
No
threshold-hys-
teresis)
Yes
High alert deactivation High alert activation
The product enables the detection of a threshold overpassed (high and low) for each probe, as described in the diagram bellow:
The sampling period (reading) enables to determine when the product will do the temperature measure and so the frequency at which the
product will detect an overpassed threshold.
No
High alert
activated?
Yes
Value >
No
high thresh-
old
Yes
Stand-by mode
No
Sampling pe-
riod reached?
Yes
Temperature
measure and saving
probe 1
Temperature
measure and saving
probe 2
Low alert activation
Sending 0x58
Value > (low
Low alert
No
threshold +
activated?
hysteresis)
Yes
Value < low
No
threshold
Yes
Low alert deactivation
No
Yes
52 of 61