TEMP V4 IP68 LoRaWAN 863-870 - Guide utilisateur / User guide version V3.1.1
5.2. Wiring a probe
In order to wire a probe, please follow these instructions:
1
2
1
3
5V + -
1 2 3 4
Remove the gland plug
CAUTION: To maintain the IP 68 it is important to screw the cable glands fully and screw the screws with a PZ.1 head
and a tightening torque of 0.9 N.m.
As a reminder the probe 1 is on the rounded side of the housing, the probe 2 is on the flat side of the housing.
*The wiring of the probes at the right place is important to match the associated registers and for the interpretation of the results (cf. Technical
Reference Manual, Registers).
Remove the
screws
2
2
1
5V + -
1 2 3 4
4
5V + -
1 2 3 4
Insert the cable of the probe supplied with
the product and connect the wires to the
terminal blocks:
• for
probe 1*
terminals 3 and 4
• for
probe 2*
terminals 1 and 2
Open the product by
FR
pulling on the cable
gland
WARNING : do not
pull on the wires
EN
59 of 61