ADEUNIS TEMP V4 IP68 LoRaWAN 863-870 Guide Utilisateur page 56

Sonde de température
Masquer les pouces Voir aussi pour TEMP V4 IP68 LoRaWAN 863-870:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TEMP V4 IP68 LoRaWAN 863-870 - Guide utilisateur / User guide version V3.1.1
WARNING: a battery must be present and connected in the product to enable this
"back-up' mode.
2.6. Timestamp of the data
The sensor can integrate the timestamp of the data in the frame if this option is
activated. Timestamp is given in EPOCH 2013 (please, refer to the TRM of the
product to know the content of each frame).
FR
To configure the timestamp, you have to set the UTC time first, via Downlink or
through the Advanced Menu of the IoT Configurator.
Then you an activate the timestamp in the Applicative parameters and choose if
you want to set the timezone and if you want that the product take into account
EN
the Daylight Saving Time.
2.7. Operation of the LED
Mode
Product in Park mode
Magnet detection process in PARK mode OFF
Product start (after detection of the
magnet)
Joining process (LoRaWAN products)
Detection of the correct wiring of the
probes at startup
Network Quality test running
Network Quality test result
Switching to the Command mode
Battery level low
Product faulty (return to factory)
Magnet detection in
PRODUCTION mode
In Class C, when the external supply is
missing at the start up of the device
JOIN process :
LED blink successively
every seconds
Red LED state
OFF
OFF
During the JOIN phase: flashing: 50ms on
/ 1 s off
If the JOIN phase is complete (JOIN
accept):
flashing: 50ms on / 50ms Off (6x)
10 seconds ON if a default is detected
10 to 20 seconds ON
Bad coverage : 10 seconds ON
Medium coverage : 10 seconds ON
Good coverage : OFF
Continuously lit
Flashing (0.5s ON every 60s)
Fixed ON
OFF
10 seconds ON
JOIN ACCEPT :
LED blink successively
every 50 ms
Green LED state
OFF
ON from detection of the magnet during 5 seconds
Rapid flashing 6 cycles, 100 ms ON / 100 ms OFF
During the JOIN phase: flashing: 50ms on / 1 s off
(just after the red LED)
If JOIN phase is complete (JOIN accept):
flashing: 50ms on / 50ms off (just before the red LED)
10 seconds ON if no default is detected
10 to 20 seconds ON
Bad coverage : OFF
Medium coverage : 10 seconds ON
Good coverage : 10 seconds ON
Continuously lit
Flashing 50ms ON / 50ms OFF after 3 seconds of
magnet detection
OFF
Probes wiring test:
During 10 seconds
If ok = green led
10 to 20 seconds
If not ok = red led
Network test:
Network test result:
LEDs during
During 10 seconds
Green= Good, Orange =
Medium, Red = Bad
56 of 61

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arf8180bcaArf8180bcb

Table des Matières