Step 2. Connect to earth (ground) system
a)
Using Underground Cable (G6270) remove 5cm (2") of plas c coa ng from one
end of the cable and connect to the green terminal on the energizer.
b)
A ach the cable to the earth system by removing 10cm (4") of insula on from
the cable at each Earth Stake (G8790), then clamp the exposed wire to each
stake using an Earth Clamp (G8760).
c)
Tighten the clamp.
Step 3. Connect the fence
a)
Connect the energizer's red output ( ) terminal to the fence using
Underground Cable (G6270).
b)
A ach the other end of the cable to the fence using a Joint Clamp (G603).
Important: If you wish to use the Output voltage informa on see the sec on
"Understanding your Energizer: Output voltage bargraph (p.9)".
Step 4. Turn the energizer on
a)
Plug the energizer into a power outlet and switch ON.
b)
Check that the Power On LED on the front of the energizer is green.
HANDY HINT
Find a loca on for your earth system that is permanently
damp, has high fer lity or salinity and is away from dairy
sheds. Install the earth system at least 10m (33 ) from
any power supply earth peg, underground telephone or
power cable.
The best construc on is 2m (61/2 ) long galvanised
stakes G8790 or Super Earth Kits G8800, 3m (10 ) apart,
connected to the energizer by high quality Lead-out
cable G6270. Do not use materials that rust.
(Use G6272 if the earth system is over 100m (300 ) from
the energizer).
G8760
G8790
9