4.6. Lock mode

To switch the CA40 lock mode on or off hold in the VOL/MUTE control for 10 seconds from
the VOL/MUTE mode. The LED SETTING indicators will flash 3 times to indicate that lock mode is
now on. When in lock mode the device cannot be managed using the VOL/MUTE control (it will flash
three times to show that it is in that mode when you turn the knob). This will protect the equipment
from unwanted handling until it is restored to normal operation after holding the VOL/MUTE control in
for a further 10 seconds (the LED SETTING indicators will flash twice to show that the lock mode is
off).
Note: once lock mode is activated it will stay activated even when the equipment is turned
off and on again. It will stay in lock mode until the VOL/MUTE control is held in for 10 seconds again.

4.7. Restore default settings and update firmware

If you would like to restore the CA40 to factory settings, follow this procedure:
1.
Switch off the equipment then press and hold the knob in.
2.
Switch the unit back on without releasing the knob. The MUTE LED indicator will flash.
3.
Wait a few seconds and then switch the CA40 off again.
4.
The next time you turn it on, the factory settings will be in the memory.
Note: for instructions on how to update the unit's firmware, see the product web page at
www.ecler.com, where you will find the update software utility and instructions on how to proceed.

5. CLEANING

The CA40 must not be cleaned with solvents or abrasive substances which may damage
the prints. Clean using a cloth moistened in water and a neutral liquid detergent, then dry with a clean
cloth. Under no circumstances allow water to enter any of the orifices in the equipment.