If the supply gas pressure is changeable or
different from the necessary pressure, you must
fit an applicable pressure adjuster on the gas
supply pipe.
Adjustment of minimum level (only for
Belgium)
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
• from natural gas G20/G25 20/25 mbar
to liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G20/G25
20/25 mbar, undo the bypass screw
approximately 1/4 of a turn (1/2 of a turn
for Triple Crown burner).
WARNING!
Make sure the flame does not go out
when you quickly turn the knob from
the maximum position to the
minimum position.
Electrical connection
• Make sure that the rated voltage and type of
power on the rating plate agree with the
voltage and the power of the local power
supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug which can hold the load that the rating
plate rates. Make sure that you install the
plug in a correct socket.
• Always use a correctly installed shockproof
socket.
• Make sure that there is an access to the
mains plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
www.zanussi.com
• There is a risk of fire when the appliance is in
connection with an extension cable, an
adapter or a multiple connection. Make sure
that the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown
(or black) phase cable to the
terminal which has a letter "L". Keep
the phase cable connected at all
times.
Connection cable
To replace the connection cable use only the
special cable or its equivalent. The cable type
is: H05V2V2-F T90.
Make sure that the cable section is applicable
to the voltage and the working temperature. The
yellow / green earth wire must be approximately
2 cm longer than the brown (or black) phase
wire.
Building In
min.
450 mm
min.
55 mm
30 mm
480 mm
10 mm
3 mm
min.
650 mm
560 mm
A
86 mm
86 mm
25