OBJ_BUCH-2369-005.book Page 43 Wednesday, November 9, 2016 1:42 PM
Troubleshooting
Online Support
http://www.bosch-indego.com
Problem
Possible Cause
Machine fails to
Possible clogging
operate
Battery not fully charged
Grass too long
Battery too hot/cold
Isolator key not inserted correctly/fully
Motor starts and
Battery not fully charged
stops immediately
Isolator key not inserted correctly/fully
Battery too hot/cold
Machine functions
Possible internal fault
intermittently
Machine leaves
Height of cut too low
ragged finish
Cutting blade blunt
Possible clogging
Areas left uncut
Time slot not long enough for garden size
Battery duration
Distance between obstacles surrounded by
perimeter wire is less than 1 m
Rough lawn conditions
Excessive vibrations/
Blade nut/bolt loose
noise
Cutting blade damaged
No charging proce-
Charging pins corroded
dure possible
Possible internal fault
Garden product una-
Perimeter wire not correctly aligned
ble to dock
Perimeter wire close to a source of interfer-
ence
The LED on docking
The perimeter wire is broken, too long or too
station flashes
short
Bosch Power Tools
Corrective Action
Check underneath the garden product and clear out as
necessary (always wear protective gloves)
Replace garden product in the docking station
Increase height of cut
Allow to cool/warm
Fit correctly
Replace garden product in the docking station
Fit correctly
Allow to cool/warm
Increase height of cut
Contact your Bosch Service Centre
Increase height of cut
Replace the blade
Check underneath the garden product and clear out as
necessary (always wear protective gloves)
Increase mowing time slot
Contact your Bosch Service Centre
Increase distance between perimeter wire
Note: Obstacles with a height of more than 6 cm do not
require to be wired
Increase/decrease cutting lane proximity from "mow set-
tings"
Tighten blade nut/bolt
Replace the blade
Clean the charging pins
Contact your Bosch Service Centre
Check perimeter wire and align it
Leave adequate distance between your perimeter wire
and source of interference (approx. 1 m)
Check perimeter wire is not broken and is between 20
and 450 meters in length. Then switch off and on power
supply.
F 016 L81 666 | (9.11.16)
English | 43