Manual setting
To be performed when you notice unsatisfactory functioning
of the Automatic operation, and it has to be done when nor-
mal environmental conditions persist in the kitchen.
Manual setting includes:
Hood calibration
Press and hold the button
indicate initiation of calibration; the process will last for
approximately 5 minutes.
Selection of the cooktop (gas , induction, or electric
Press and hold simultaneously the buttons
buttons
,
and
Within this timeframe, press:
Button
in case of gas cooktop
Button
in case of electric cooktop
Button
in case of induction cooktop
The preselected button remains lit to indicate the selection
was performed, after 10 seconds the button flashes briefly to
indicate that the performed selection was recorded.
Indicators of Filter Saturation
At regular time intervals, the hood signals indicate the need to
perform filter maintenance.
on with steady light: perform grease filter
Button
maintenance.
Button
flashing: perform activated charcoal filter
maintenance.
NOTE: Filter saturation signal is visible within the first minute
after switching off the hood; within this time, the reset of
saturation indicators must be performed.
Reset of filter saturation indicators:
Press and hold the button
Activation of saturation indicator activated charcoal filter
NOTE: This operation must be performed with the hood off.
This indicator is normally deactivated; press and hold the
button
to activate the function: the button lights
up with steady light.
To deactivate the function, press and hold the button
button lights up flashing.
10
, all button LEDs flash to
and
start flashing for 5 seconds.
.
CFM Reduction System
Before operating your hood:
Some States and Provinces of the US & Canada restrict the
maximum exhausting airflow of range hoods.
Airflow is measured as cubic feet per minute (CFM).
These maximum levels allowed are detailed in the local code of
your area. Please check local codes to find out if you need to
restrict the maximum airflow of your hood. If your local code
mandates a maximum airflow level below the maximum airflow
:
of this hood (i.e. 600 CFM), please execute the procedure below
to reduce the maximum airflow.
1
Turn the motor OFF.
1
Press the ON/OFF (1) and Intensive speed (5) buttons
2
together for 3 seconds.
You will hear a beep and all control lights will illuminate
for 3 seconds.
This action will Disable speeds 3 and 4 and effectively
lower the Maximum airflow to >300 CFM.
Locate the CFM certification sticker in the hardware pack.
3
4
Peel and Affix this sticker to a visible area in the blower.
This sticker provides official certification to your local
inspector that this hoods maximum airflow has been
reduced to >300 CFM.
: the