Mechanical room hygrostat HYGRASREG
micro switch as two-position controller with humidity sensor) working without external
voltage, with humidity measuring element made of stabilized synthetic gauze, optional
with setpoint setter for switchpoint adjustment (external or internal setting) in an
elegant enclosure made of plastic, with snap-on lid, base with 4-hole attachment for
installation on vertically or horizontally installed in-wall flush boxes, with predetermined
breaking point for on-wall cable entry. HYGRASREG
monitoring the relative humidity in office and residential rooms, baths, labs, control
cabinets, computer rooms, etc., as minimum or maximum hygrostat. It is applied in
dust-free, pollutant-free, non-aggressive air.
TECHNICAL DATA:
Power supply: ........................ 24 ... 230 V AC
Setting range: ....................... 25 ...95 % r. H.
Switching capacity: ................. dehumidifying, 5 (0.2) A, min. 100 mA
(Contact load)
Contact: ............................... 1 changeover contact, (potential-free)
Sensor element: .................... plastic fibres
Operating difference: ............... ca. 4 % r. H.
Tolerance: ............................. max. 3 % r. H.
Enclosure temperature: ........... 0 °C ...+40 °C
Enclosure: ............................. plastic, material ABS,
Dimensions:
Electrical connection: ............. 0.14 - 2.5 mm
Installation: ........................... wall mounting or on in-wall flush box Ø 55 mm,
Protection class: .................... II (according to EN 60 730)
Protection type: ..................... IP 30 (according to EN 60 529)
Standards: ............................ CE conformity,
FUNCTION:
Humidifying: ........................... wire terminals 1 and 3
Dehumidifying:........................ wire terminals 1 and 2
Type ⁄ WG2
Setting Range
Humidity
RH - 2
R H - 2
25 ... 95 % r. H.
RH - 2 U
R H - 2 U
25 ... 95 % r. H.
®
RH-2 with switching output (with single-pole
®
RH-2 is used for controlling and
> 24 V in dry rooms only according to VDE 0110
humidifying, 3 (0.2) A, min. 100 mA
colour pure white (similar RAL 9010)
98 x 106 x 34 mm (Frija II, with potentiometer)
2
,
via terminal screws on circuit board
base with 4-hole for mounting on vertically or
horizontally installed in-wall flush boxes for cable
entry from the back, with predetermined breaking
point for on-wall cable entry from top ⁄ bottom
in case of plain on-wall installation
EMC directive 2004 ⁄ 108 ⁄ EC,
low-voltage directive 73 ⁄ 23 ⁄ EEC
Hysterese
ca. 4 % r. H.
ca. 4 % r. H.
Connecting diagram
Ausgang
Steps
1x Changeover contact
one-step
1x Changeover contact
one-step
RH - 2
Item No.
External setting
1 2 0 2 -4 02 0 -0 0 1 0 -0 0 0
Internal setting
1 2 0 2 -4 02 0 -0 0 2 0 -0 0 0