6
Handling and operation
The WIESEL POWERLine ZRT
movements with great force. Structures in the sliding carriage can lead to injuries, e.g.
crushing of limbs, or to damage through collision with other parts of the system. Proceed with
the utmost caution during first start-up.
When a linear drive unit is operated with only short travel (<100mm) always at the same
place, sufficient lubrication is not ensured. In this case, carry out a movement over the entire
range of movement at regular intervals, after about 250 to 500 double travels.
During operation, occasionally check the correct function of the linear drive unit by visual
inspection.
The operating and supervisory staff are duty bound to inspect the linear drive units or system
for outwardly visible damage or faults at least once a shift. Any changes (including changes in
the operating behaviour) that could affect safety must be reported at once.
7
Faulty operation
In the case of faulty operation, the operating sequence must be inspected by experts, and if
necessary commissioning must be repeated. Pay special attention to the notes in Chapter 5
"Commissioning" to avoid injury and damage.
WIESEL POWERLine ZRT
®
mechanical linear drive units can carry out fast linear
®
42/08
Handling and operation
33