Quick Instructions For Use Of The Sauna Heater; Check Before Taking A Sauna Bath; Operation Of The Sauna Heater Controls; Information For Users - Helo SAGA ELECTRO Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
Installation and User Manual SAGA ELECTRO

1. Quick instructions for use of the sauna heater

1.1. Check before taking a sauna bath

1.
The sauna room is suitable for taking a sauna bath.
2.
The door and the window are closed.
3.
The sauna heater is topped with stones that comply with the manufacturer's recommendations, the heating
elements are covered with stones, and the stones are piled sparsely.
NOTE! Ceramic rocks are not allowed.

1.2. Operation of the sauna heater controls

The control panel T2 and Contactor box WE 14 is installed outside the sauna room.
For more detailed installation guide, refer to the specific control panel and contactor box operating instructions.

2. Information for users

Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge about how the
device is operated (e.g. children), should only operate the device while supervised or according to
instructions given by the persons in charge of their safety.
Make sure that children aren't playing with the sauna heater.

2.1. Sauna room

The walls and ceiling of a sauna room should be thermally well insulated. All surfaces that store heat, such as tiled and
plastered surfaces must be insulated. It is recommended to use wooden panel cladding inside the sauna room. If there
are heat storage elements in the sauna room, such as decorative stone, glass etc., note that these elements may extend
the pre-heating period even though the sauna room is otherwise well insulated (see page 5, section 3.1 Preparing for
sauna heater installation).

2.2. Rekommenderad ventilation i bastun

Image. 1 Recommended sauna room ventilation
1. Sauna room
2. Washroom
7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing.
Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with (i.e. cool down) the
sauna heater's thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn't fitted with forced ventilation. In this case, the exhaust
valve is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER'S CONTROL THERMOSTAT IS LOCATED
IN THE SAME ZONE.
3. Electric sauna heater
4. Exhaust valve
5. Exhaust flue or channel
6. Door to the sauna room
3

Publicité

Table des Matières
loading

Table des Matières