Calibration
4
Use double-sided tape to attach a spirit level to the center of the spider arm.
Attach it so the air bubble is in the center of the level.
Attach the spirit level near the crank shaft to calibrate the left side.
5
Remove the calibration weight.
6
Remove the calibration pedal bolt.
7
Point the crank arm down and adjust the angle so the level indicates it is perpendicular.
8
In the sensor screen of the SGX-CA900, tap [Pedaling Monitor R] and then [Calibration (Precision Zero)]
in order.
This product has a correction function for the zero point gap caused by varying temperatures.
The accuracy of this function improves when the sensor is recalibrated for different temperature conditions. The result is initialized by
calibrating a highly precise zero point.