Duct Station
A
B
C
D
E
F
G
H
I
J
K
A Backdraft Damper, Part No. 58786 (obtain locally),
should be installed in a 10.2 cm (4 inch) diameter
VERTICAL duct system. This will prevent a backdraft
when dryer is not in use, and will keep the exhaust air
in balance within the central exhaust system.
Step 3: (Gas Dryer Only) Connect Gas
Supply Pipe
WARNING
To reduce the risk of gas leaks, fire or
explosion:
• The dryer must be connected to the type
of gas as shown on nameplate located in
the door recess.
• Use a new flexible stainless steel
connector.
• Use pipe joint compound insoluble in L.P.
(Liquefied Petroleum) Gas, or Teflon tape,
on all pipe threads.
• Purge air and sediment from gas supply
line before connecting it to the dryer.
Before tightening the connection, purge
remaining air from gas line to dryer until
odor of gas is detected. This step is
required to prevent gas valve
contamination.
• Do not use an open flame to check for gas
leaks. Use a non-corrosive leak detection
fluid.
• Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
512681
Minimum Diameter of
Collector Duct
10.2 cm (4 inches)
20.3 cm (8 inches)
22.9 cm (9 inches)
25.4 cm (10 inches)
27.9 cm (11 inches)
30.5 cm (12 inches)
32.6 cm (13 inches)
35.6 cm (14 inches)
38.1 cm (15 inches)
38.1 cm (15 inches)
40.6 cm (16 inches)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1. Make certain your dryer is equipped for use with
the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a
3/8 inch NPT gas connection.
NOTE: The gas service to a gas dryer must
conform with the local codes and ordinances, or in
the absence of local codes and ordinances, with the
latest edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54 or the CAN/CSA-B149.1 Natural
Gas and Propane Installation Code.
Natural Gas, 37.3 MJ/m
be supplied at minimum 5.0 inch water column
pressure to maximum 10.5 inch water column
pressure.
For proper operation at altitudes above 610 m
(2000 feet) the natural gas valve spud orifice size must
be reduced to ensure complete combustion. Refer to
Table 2.
Natural Gas Altitude Adjustments
Altitude
m
feet
610
2,000
915
3,000
1,680
5,500
2,135
7,000
2,745
9,000
3,200
10,500
2. Remove the shipping cap from the gas
connection at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.
3. Connect to gas supply pipe.
W316
Installation
3
3
(1000 Btu/ft
), service must
Orifice Size
#
mm
inches
41
2.44
0.0960
42
2.37
0.0935
43
2.26
0.0890
44
2.18
0.0860
45
2.08
0.0820
46
2.06
0.0810
Table 2
Part
Number
503776
503777
503778
58719
503779
503780
15