Place the dryer in position, and adjust the legs until the
dryer is level from side to side and front to back.
Leveling legs can be adjusted from inside the dryer
with a 1/4 in. driver. All four legs must rest firmly on
the floor so the weight of the dryer is evenly
distributed. The dryer must not rock.
1
1
Dryer Base
2
Level
3
Leveling Leg
4
Rubber Foot
Figure 4
IMPORTANT: In mobile home installations, gas
dryers MUST be permanently attached to the floor
at the time of installation. Order No. 526P3 Hold
Down Kit (available at extra cost) for a
manufactured (mobile) home installation. Follow
the instructions supplied with the kit.
Installation of unit must conform to the Manufactured
Home Construction and Safety Standards, Title 24
CF4, Part 32-80 or Standard CAN/CSA-Z240 MH.
10
2
3
4
D678I
D678I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Step 2: Connect Dryer Exhaust System

WARNING
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.
To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
WARNING
This gas appliance contains or produces a
chemical or chemicals which can cause
death or serious illness and which are
known to the State of California to cause
cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in
the fuel or from fuel combustion, make sure
this appliance is installed, operated, and
maintained according to the instructions in
this manual.
To reduce the risk of fire, DO NOT use
plastic or thin foil ducting to exhaust the
dryer.
To reduce the risk of fire, the exhaust duct
and weather hood MUST be fabricated of a
material that will not support combustion.
Rigid or flexible metal pipe is recommended
for a clothes dryer.
WARNING
To reduce the risk of fire due to increased
static pressure, we do not recommend
installation of in-line secondary lint filters
or lint collectors. If secondary systems
are mandated, frequently clean the
system to assure safe operation.