position the skimmer in the sump
-
feed water into the skimmer compartment (if applicable)
-
open the water level adjuster fully by turning it clockwise
-
start the skimmer pump
-
turn the water level adjuster anti-clockwise until fine bubbles are visible between the
-
bayonet and the bottom of the skimmer cup (diagram c)
initially keep the foam level in the skimmer cup low to avoid over skimming and
-
possible flooding of the cup
wait a minimum of 24 hours before the final adjustment
-
turn the water level adjuster in or out until the fine air bubbles start
-
approximately half way up the cups riser tube
for dry foam turn the water level adjuster clockwise
-
for wet foam anti-clockwise
-
Important: Never allow the pump to run dry.
-