22 | English
Troubleshooting
Cause
Corrective Measure
Signal LED 2 does not illuminate
Measuring tool is not
Slide the On/Off switch into position "On".
switched on
Measuring tool has
Slide the On/Off switch first into position "Off" and
switched itself off
then into position "On".
Batteries have not
Insert batteries. Pay attention to the polarity.
been inserted or
been inserted incor-
rectly
Flat or rechargeable
Replace batteries. Do not use rechargeable
batteries inserted
batteries.
Signal LED 2 illuminates yellow or red, even though no metal is
located within the vicinity (warning of metal objects)
Ambient tempera-
Only use the measuring tool within the specific
ture is too high/too
temperature range of 0 °C –40 °C .
low
Severe temperature
Wait until the measuring tool acclimates to the
change
ambient temperature.
Auto calibration not
Perform a manual calibration.
successful
Signal LED 2 lights yellow or red over large measuring area on the
wall (warning of metal objects)
Many, closely
Pay attention to the pitch of the signal sound to dif-
spaced metal ob-
ferentiate between individual metal objects. Metal
jects
objects that are too closely spaced, cannot be de-
tected separately.*
Metal as building
A reliable detection is not possible with metallic
material
building materials (e.g. foil-laminated insulation
materials, heat sinks).*
Auto calibration not
Perform a manual calibration.
successful
2 609 140 996 | (23.9.13)
Causes and Corrective Measures