BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
6
IO-Link-Smart Sensor Profile (BML SL1-ALZ0-U1ZZ-...) (continued)
6.5.5

Process data structure (PD Input Descriptor)

This parameter describes the composition of the process
data variables used.
BML SL1-... processes the process data variable as
follows:
Subindex
Values
0x03
0x01
0x20
0x00
Tab. 6-6:
Process data structure
6.5.6

Diagnostic data

Index
Subindex
Parameters
0x0028 (40)
0
Process Data Input
Tab. 6-7:
Diagnostics parameters
6.6

Error messages

The following error messages are stored for failed
parameterization:
Error code
Error message
0×8011
Index not available
0×8012
Subindex not available
0x8020
Service temporarily not available
0×8030
Value out of range
0×8033
Parameter length overrun
0×8034
Parameter length underrun
0×8036
Function temporarily unavailable
Tab. 6-8:
IO-Link specification error messages
www.balluff.com
Description
Signed Integer
32 bit length
0 bit offset
Size
Access
4 bytes
Read Only
Values
This parameter contains the current position value
or the last position value before an error occurred.