Technical data

The information here comprises values at room
temperature in conjunction with magnetic tape
BML TSC-ALCZ-1ZZZ-M_ _ _ with a gap of 0.4 mm over
the magnetic tape (without cover strip).
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
10.1
Accuracy
Position resolution
IO-Link interface
BML SL1-ALZ_-
U_ZZ-_U1L-_ _
BiSS/SSI interface
BML SL1-ALZ1-
_ _ZZ-ABA
Analog, incremental
real-time signal BML SL1-
ALZ0-U1ZZ-AU1L
Repeat accuracy
Hysteresis
Max. non-linearity of sensor
head
Linearity deviation
of entire system (sensor
head + magnetic tape)
Temperature coefficient of
the entire system
Movement speed
40
english
1 µm
1000/1024 µm
Period 2 mm
< 1 μm
≤ 1 μm
±5 μm
see Section 4.3.3 and
Section 4.3.4
10.5 ppm/K
Max. 10 m/s
10.2

Ambient conditions

Operating temperature
BML-ALZ0....
BML-ALZ1....
Storage temperature for
sensor head
Cable temperature rating
Shock rating
Continuous shock
per EN 60068-2-27
2)
Vibration load per
EN 60068-2-6
2)
Noise per EN 60068-2-64
2)
Degree of protection per
IEC 60529 (with
screwed-on connector)
External magnetic fields
Relative humidity
10.3

Power supply

Supply voltage
3)
BML SL1...
...-ALZ_-U_ZZ-_U1L-...
...-ALZ1-__ZZ-ABA1-...
...-ALZ1-__ZZ-ABA5-...
Current draw
4)
at 24 V
5)
at 5 V
5)
Power consumption
Polarity reversal protection
Overvoltage protection
Dielectric strength (GND to
housing)
Switch-on delay (system
ready) after applying supply
voltage
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
sea level.
2)
) Individual specifications as per Balluff factory standard, resonant
frequencies excluded
For
: The sensor head must be externally connected via a limited-
3)
energy circuit as defined in UL 61010-1 a low-power source as defined in
UL 60950-1 or a Class 2 power supply as defined in UL 1310 or
UL 1585.
Without controller current draw
4)
Supply voltage
5)
1)
–10 °C...+70 °C
–20 °C...+70 °C
–25 °C...+85 °C
–25 °C...+80 °C
100 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
20 g, 5...2000 Hz
IP67
– < 30 mT (to avoid
permanent damage)
– < 1 mT (to avoid
influencing the
measurement)
90% RH, condensation not
permitted
18...30 V
10...30 V
5 V ±10 %
70 mA
170 mA
≤ 1.4 W
No
No
500 V DC
100 ms