SHOWER MIXER MAINTENANCE
OUR ADVICE:
Regularly turn at least once a week the shower mixer control knob to the extreme limit positions (15°/50°) to prevent the
cartridge from getting clogged by sludge deposits.
THE THERMOSTATIC SHOWER MIXER CARTRIDGE
To prevent any operating abnormality due to a sludging of the mixer, perform the two simple ope−
rations below:
A − Frequently move the shower mixer control knob to the two extreme limit positions.
B − Regularly clean the thermostatic shower mixer cartridge (at least every 6 months and even
more often if you live in a region where the water contains hard water deposits).
1. Turn off the incoming
hot and cold water pipes.
Drain the thermostatic
shower mixer by opening
the incoming water fau−
cet to lower the pressure
and thus facilitate the
removal of the cartridge.
Use a flat head screwdri−
ver to loosen and remove
the setscrew located in
the mixer base.
B/ operate several times before unscrewing
C/ clean the inside of the cartridge
2. Apply a little hand
pressure to the front of
the cartridge to release
the fork clip.
IN THE EVENT OF BLOCKAGE OF THE CARTRIDGE
3. Protect the column by
inserting a piece of card−
board under the pin and
then carefully pull this pin
down.
A/ remove the O−ring before unscrewing
D/ grease the O−ring and move it around seve−
ral times inside the bodyć wazelinę na O−krążek
i kilkukrotnie obrócić go w miejscu
4. Remove the cartridge
assembly (cartridge with
its container) and dip it in
vinegar. Apply a little
vaseline to the seals
before reinstalling.