ATTENTION!
Incorrect voltage will destroy the device: Pin 1: Power (+18...30 VDC)
!
Electrical connection
M12 / 12-pin, A-coded
1: PWR (+18...30 VDC) Brown
2: Ground
Blue
White
3: IN1 (Trigger)
4: OUT1
Green
5: IN2
Pink
6: OUT2
Yellow
The duration of the output signals and the time of output are adjusted by software and
depend on the current job.
Ethernet connection
NOTE
To avoid network
malfunctions, ensure that
each IP address is unique
within your network!
1)
7: OUT3
Black
8: IN3
Gray
9: OUT4 / RS485+ Red
10: IN4
Violet
11: IN5
Gray-Pink
12: OUT5 / RS485- Red-Blue
Start the Application Suite . The VeriSens
must be connected to the same network. By default, the
use of DHCP is enabled. If a DHCP server is not found
within 15 seconds, the following network configuration
is used:
IP address:
Subnet mask:
For more information, please see page 10.
English
Pin 2: Ground
Ethernet
Electr. connection illumination
1)
M12 / 4-pin
1: TD+
1: +24 V or +48 V Flash
2: RD+
2: +12 V or +24 V Flash
3: TD-
3: Ground
4: RD-
4: Flash Sync
on device
1)
voltage outputs configurable by software
2)
192.168.0.250
255.255.255.0
1)
M8 / 4-pin (XC only)
2)
®
and your PC
EN
EN
5 5