Operating And Indicating Elements - IFM Electronic ecomat200 FD-2 Notice D'utilisation

Masquer les pouces Voir aussi pour ecomat200 FD-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FD-2
MONITOR

4. Operating and indicating elements

1
7
MONITOR FD-2
Frequency /Direction
4
In 1
In 2
6
13
19
1 Display (7/14-segment)
1a Indicators for input channels and operating modes:
CH1...CH4
RUN
PRG
TST
KEY
1b Display:
1c Display:
2 Push buttons
/ : Selection of the actual value display, parameter selection,
3 Push button
:
4 LEDs In1/2 (yellow): indicate input pulses
5 LEDs Out1/2 (green): Switching status of the outputs 1 and 2
Off:
On:
Quickly flashing:
Slowly flashing:
6 Panel for labelling
page 22
2
3
4
5
6
8
9
10
11
12
CH1CH2 CH3 CH4 RUNPRG TST KEY
Out1
Out2
14
15
16
17
18
20
21
22
23
24
Input channels (here: CH1 and CH2)
Run mode (normal operating mode)
Programming mode (setting of the parameter values)
Test mode (only optional)
Status of the unit (locking)
Actual values and parameter values (5-digit, numerical)
Rotational speed: 0...60,000 RPM / frequency: 0.1...1000.0 Hz (CH1)
Direction of rotation: 0DIR = no direction or pulse sequence detected
Outside the value ranges the display shows "----".
Parameter abbreviation and units (3-digit, alphanumeric)
setting of the parameter values
Selection of the operating mode,
acknowledgement of the parameter value, front reset
The output is not switched (relay de-energised, transistor blocked)
The output is switched (relay energised, transistor switched)
The output is kept latched (parameter SOP, Store Output)
The delay time is effective for the output. The output switches when the
delay time has elapsed and the trigger event is still present
(parameter DTx, Delay Time)
CH1CH2 CH3 CH4RUNPRG TST KEY
1
2
3
1a
5
1DIR = IN1 before IN2
2DIR = IN2 before IN1
1b
1c