Télécharger Imprimer la page

Device Information - Dimplex PKS 14Econ Instructions D'installation Et D'utilisation

Station de rafraîchissement passif à l'intérieur au niveau d'une pompe à chaleur eau glycolée/eau

Publicité

Les langues disponibles

Les langues disponibles

PKS 14Econ - PKS 25Econ

7 Device information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection in accordance with EN 60 529
2.3
Installation location
2.4
Performance levels of pump
2.5
Controller / extension module
3
Performance data
3.1
Operating temperature limits:
Cooling water
Brine (heat sink)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of cooling water (flow/return) at B10 /WE20K
3.3
Cooling capacity
3.4
Cooling water flow rate with an internal pressure differential of
3.5
Brine flow with an internal pressure differential of (heat sink)
3.6
Free compression (pump max. level)
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections for heating system
4.3
Device connections for heat source
4.4
Weight of the transportable unit(s) incl. packaging
5
Electrical connection
5.1
Supply voltage / fuse protection
5.2
Control voltage / fuse protection
5.3
Nominal power consumption (max. pump level)
6
Complies with the European safety regulations
1. This data indicates the size and capacity of the system. The specified values, e.g. B5 / WE20, have the following meaning: Heat sink temperature of 5°C and cooling water return
temperature (water inlet) of 20°C
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
EN-5
°C
°C
1
at B5 / WE20
kW
1
at B10 / WE20
kW
1
at B15 / WE20
kW
m³/h / Pa
m³/h / Pa
Pa
2
H x W x L mm
Inches
Inches
kg
W
452231.66.25 · FD 9303
PKS 14Econ
Passive cooling station
IP 20
Inside
3
External / internal
+5 to +40
+2 to +15
Monoethylene glycol
25%
8.2
19.3
13
6.5
1.3 / 8000
2.5 / 29800
28000
320 x 650 x 400
Thread 1 1/4" external
Thread 1 1/4" external
30
- / -
1~/N/PE 230V (50Hz)/
C13A
200
3
PKS 25Econ
Passive cooling station
IP 20
Inside
3
External / internal
+5 to +40
+2 to +15
Monoethylene glycol
25%
7.0
34.8
23.7
7.8
2.9 / 17000
3.6 / 29000
17000
320 x 650 x 400
Thread 1 1/4" external
Thread 1 1/4" external
32
- / -
1~/N/PE 230V (50Hz)/
C13A
200
3

Publicité

loading

Ce manuel est également adapté pour:

Pks 25econ