Gb.9.2.2 Micro Filter; Gb.9.2.3 Exhaust Filter; Gb.9.3 Changing The Power Cord; Gb.9.4 Spares And Accessories - Nobles Tidy-Vac 607961 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
The suction hose coupling may now be reinserted into the tank
socket - insert the coupling and lock into position by rotating
clockwise.
GB.9.2.2
Micro filter
The micro filter is secured in position above the motor by means of a
simple press fitting. Two recesses, in the motor hood, below the
GB.10.
TROUBLE SHOOTING
PROBLEM
Machine does not operate
Poor vacuum performance
Poor brush pick-up.
(02-00)
CAUSE
Faulty power cord.
Faulty On/Off switch.
Loose wiring.
Building circuit breaker tripped.
Internal thermal overload sensor tripped.
Worn carbon brushes in vacuum motor.
Defective vacuum motor.
Full bag.
Clogged cartridge filter.
Loose vacuum hose connections.
Defective vacuum hose.
Tank lid not closed tightly.
Clogged hose.
Clogged tank coupling.
Entangled debris in brush.
Worn brushes.
Worn nozzle wheels.
Home
Find... Go To..
Vacuum cleaner/ Aspirateur à poussière/ Aspiradora Tidy-Vac
cartridge filter, on the left and right sides, allow you to insert the middle
fingers of both the left and right hands and gently pull upwards on the
underside of the cartridge filter. To replace the new or cleaned
cartridge simply push it gently downwards onto the mounting ring.
GB.9.2.3
Exhaust filter
The exhaust filter is designed to primarily filter the carbon dust from the
carbon brushes of the motor. It is situated on the front of the machine,
in the chassis, under the tank socket. Pull the filter outwards by firmly
holding onto the black plastic tab/handle. Open the filter frame which
now exposes the filter fleece. Replace the fleece, close the frame and
reinsert it into the machine.
The exhaust filter should be changed at least every six months.
GB.9.3
Changing the power cord
A damaged cord can be easily replaced. After disconnecting the
plug from the main power supply, turn the machine over to expose
the chassis. Slide the plug retaining clip forwards and flip upwards
to expose the plug. Remove the old plug with cord and reinsert the
new plug with cord. Flip the retaining clip down and slide it back. A
click will be heard once it is in position.
FOR SAFETY:
When servicing machine, unplug cord
from wall outlet. Use manufacturer supplied or approved
replacement parts.
GB.9.4
Spares and accessories
Should you require spares, accessories or consumables, please
contact your distributor.
SOLUTION
Change power cord.
Contact Service Center.
Contact Service Center.
Reset circuit breaker.
Remove air obstruction. Let motor cool for 10
minutes.
Contact Service Center
Contact Service Center
Replace bag.
Replace secondary filter.
Tighten hose connections.
Replace hose.
Close lid.
Remove clogged material.
Remove clogged material.
Remove clogged material.
Replace brush strips.
Replace wheels.
7

Publicité

Table des Matières
loading

Table des Matières