the keypad will start beeping to indicate
that learn mode has been activated.
2. Press the ARM button
control
it will send a transmission signal. The
panel will confirm if a user is found with
the message "Found".
3. Press
to confirm.
4. Repeat the actions 1 - 3 to follow up for all
5 buttons (use the navigation button
switch to the next user number).
For remote control 2 take user numbers 26 -
30 etc.
Telephone connection
To transmit events, the system needs to be
connected to a telephone line. Follow steps
8 - 9 to program the telephone numbers.
If no telephone line is connected, the dialer
must be turned off:
1. Press
175
1
"Dialer A Option 12----7-".
2. Press 1
the display shows: "-2----7-".
3. To check: press
the display changes to clear text mode
and shows "Enable Dialer No".
4. Press
to go back and continue with
step 10 "Testing Installation".
Telephone numbers
The telephone numbers (max. 8) which are
dialed in case of an event can be up to
16 digits long. Default setting: Telephone
number 8 is the call back number of the
Control Monitoring Station (CMS).
1. Telephone number 1:
press
181
1
2. Choose a reporting format for this number.
a) Number related to a phone:
press
182
1
an alarm signal will be sent out to this
number when an event occurs.
b) Call goes out to a CMS station:
CID format: press
SIA format: press
3. Repeat actions 1 - 2 to follow up for
telephone numbers 2 - 8 (use the naviga-
Siemens Building Technologies
Fire Safety & Security Products
on the remote
the display shows:
simultaneously
Ctrl
"tel.number"
2
182
1
1
182
1
10
tion button
phone number).
There are 11 different reporting formats that
can be selected for each telephone number.
The formats are listed in the Installer Manual.
Identification code
When connected to a monitoring station you
can program an individually identification
code:
to
Area A: press
(4 digit code 0-F).
Testing Installation
To test the strength of the signal received on
the panel: press
Any time a signal is detected, the keypad
beeps and displays the received signal
strength in % for 30 sec.
To test all detectors on their function and
transmission range, change to walk test
mode.
In the walk test mode the panel will not
send out any alarms and the working
range will be less than in the normal op-
erating mode - EN50131 requirement.
1. Start walk test: press
the keypad will start beeping to indicate
that walk test mode has been activated.
2. Activate the installed detectors with a
magnet
it will send a transmission signal (for more
details see Installation Instruction of the
detector). The panel will give a notification
signal each time a detector signal is re-
ceived and will show the detector number
on the display.
3. To end this mode: press
this will take you back to the normal mode.
4. To check out all received signals in event
log: press
5. To clear events in the log: press
enter the installer code (see User Manual
3.15.3).
The programming is finished now and the
system ready to operate.
Don't forget to reconnect the internal siren!