Max. temperature ranges
Max. ambient temperature range T
Max. medium temperature range T
1) -40 °C [-40 °F] only valid when no sealing is used.
Sealings from NBR only admissible from -30 °C [-22 °F] ... +100 °C [+212 °F].
Sealings from FPM/FKM only admissible from -15 °C [5 °F] ... +102 °C / 105 °C [215 °F / 221 °F].
2) For IP code IP67 the ambient temperature range is limited to -40 °C ... +80 °C [-40 ... +176 °F].
3) A maximum medium temperature of 102 °C [215 °F] or 105 °C [221 °F] for T4 ... T1 is permitted if the pressure transmitter is installed in such a way that its
temperature above the hexagon of the process connection does not exceed 102 °C [215 °F] or 105 °C [221 °F].

4. Transport, packaging and storage

4.1 Transport
Check the pressure transmitter for any damage that may have been caused during transportation.
Obvious damage must be reported immediately.
Fit the protective cap before transporting the instrument in order to protect the process connection from damage.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for
repair).
Fit the protective cap before storing the instrument in order to protect the process connection from damage (for
model E-11).
WIKA operating instructions pressure transmitter, models E-10 and E-11
E-10-*-***-**-**CX**-**
1) 2)
E-11-*-***-**-***CX**-**
T1 ... T4
-40 ... +105 °C [-40 ... +221 °F]
amb
T5
-40 ... +75 °C [-40 ... +167 °F]
T6
-40 ... +60 °C [-40 ... +140 °F]
T1 ... T4
-40 ... +105 °C [-40 ... +221 °F]
medium
T5
-40 ... +75 °C [-40 ... +167 °F]
T6
-40 ... +60 °C [-40 ... +140 °F]
E-10-*-***-**-**DX**-**
E-11-*-***-**-***DX**-**
T1 ... T4
-40 ... +102 °C [-40 ... +215 °F]
T5
-40 ... +75 °C [-40 ... +167 °F]
T6
-40 ... +60 °C [-40 ... +140 °F]
T1 ... T4
-40 ... +105 °C [-40 ... +221 °F]
T5
-40 ... +75 °C [-40 ... +167 °F]
T6
-40 ... +60 °C [-40 ... +140 °F]