9. Specifications
Specifications
Load in Ω
Output signal 4 ... 20 mA
Output signal DC 0 ... 5 V
Output signal DC 0.5 ... 4.5 V
Output signal DC 1 ... 5 V
Output signal DC 0 ... 10 V
Voltage supply
Supply voltage
Max. power consumption
Dynamic behaviour
Settling time per IEC 61298-2
Short-circuit resistance
Reverse polarity protection
Insulation voltage
Material (wetted)
Model E-11 and E-10 with
measuring range ≤ 25 bar
Model E-10 with measuring range
> 25 bar, NACE-compliant
Sealing
Material (in contact with the environment)
Case
Cable
WIKA operating instructions pressure transmitter, models E-10 and E-11
≤ (supply voltage - 10 V) / 0.02 A
> maximum output signal / 1 mA
> 100k
> 100k
> maximum output signal / 1 mA
→ See product label
1 W
≤ 2 ms
≤ 10 ms
For model E-10 with measuring range ≤ 0 ... 25 bar at medium temperature < -30 °C
[-22 °F]
For model E-11
S + vs. U -
U + vs. U -
DC 500 V
Stainless steel
Stainless steel
Elgiloy
→ See "Process connection"
Stainless steel
→ See "Electrical connection"
EN
23