Setting Into Operation; How To Set The Automatic Humidity Control; Cleaning - Kroll TE40 Notice D'instruction

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TE40
anticlockwise. The flash above the knob shows
approximatively reached humidity-degree by a
click sound.

2.7 Setting into operation

1
8
1
Working hours-meter
2
Normal operation dehumdifying
3
Sensor malfunction
4
Defrosting
5
System OFF by excess temperature
6
Drip pan overfilled
7
System OFF by hygrostat
8
Power cord with plug
9
Main switch
10
Hygrostat connector
11
Voltage switch
12
Circuit breaker
LED - „Defrosting"
The compressor turns, the fan is of. After defros-
ting the device switches on again.
The device is equipped with an indication for
eventual malfunction of the sensing elements,
which control important values. In case of a faulty
sensing element, the device will turn off and the
LED „Sensor malfunction" will flash.
Connect mains plug to a socket with
16/Amp. fuse and earthing contact. Adjust
appliance to desired room humidity level.
Turn main switch to ON. The appliance works
permanently.
10
2 3
4
5
6
9
Attention
2.7.1 How to set the automatic humidity
control
1.
Your Dehumidifier can be equipped with an
adjustable humidistat (hygrostat) (in option).
When the hygrostat is not connected, the
7
appliance works also, but without automatic
control.
2.
The humidistat knob turns clockwise.The
size of the room, the relative humidity and
the temperature will influence your setting.
Start it first by selecting the midway posi-
10
tion.
3.
Once set into operation,the device works
until the set humidity is reached. Then the
unit will stop and start by itself. It is maintai-
ning the humidity you have selected.
4.
If you want to remove more moisture, rotate
knob clockwise.
5.
In extreme conditions, rotate the knob
clockwise to final position. At this setting,
your dehumidifier will operate continuously
regardless of the amount of moisture in the
air.

2.8 Cleaning

Always unplug power supply plug before wor-
king on the electrical system.
All work on the electrical installation must be
carried out by a qualified electrician
For cleaning, please use brush or compressed-
air, don´t use water or dissolvent.
The dirty air-filter can be washed out in water
with detergent. Let it dry completely and then
mount it again into the device.
English
Attention
Attention
h

Publicité

Table des Matières
loading

Table des Matières