1-8) Outputs for the solenoid valves
9-16) Inputs for the Start/Pause buttons
17) Data connection leading to the CTX
Fig. 9: Electrical connections of the relay unit
5.3 C
onnecting circuit of the solenoid valves
The solenoid valves should be connected to the
terminals of the electronic board as indicated in
Fig. 9. Use a 12Vdc solenoid valve with a maximum
absorption of 8W. Use cables with a cross section
of 1.5 – 2.5 mm
2
. A cross section of 1.5 mm
suffice if the length of the solenoid valve's
connecting cables is less than 20 m.
5.3.1
Connections with the warning notice
function
If the CTx is configured to have the warning notice
function, the even numbered outputs should be
used for the warning notice of the preceding odd
numbered outputs. The connection diagram is
indicated in Fig. 10.
5.4 Connecting circuit of the shower
Start/Pause buttons
Fig. 9 and Fig. 10 show the typical diagram for
connecting the Start/Pause buttons. The buttons to
be used should be normally open. If you do not
wish to use the buttons, simply do not connect
them.
00182-M03-03-ML - Manuale installazione CT4xw-6xw-8xw
1-4) Outputs for the solenoid valves
5-8) Inputs for the Start/Pause buttons
9) Data connection leading to the CTx
Fig. 10: Electrical connections of the relay unit with
warning notice enabled
6
I
NSTALLATION OF THE SOLENOID VALVE AND
FILTER
For mounting (Fig. 11) follow the instructions
below:
2
will
When mounting the solenoid valve and the filter
pay attention to the arrow found on each of
them, which indicates the direction of water flow.
The filter should be installed before the solenoid
valve in order to prevent impurities from
reaching the valve.
The solenoid valve can function in any position
however it is advised to point the coil facing
upwards in order to prevent impurities from
accumulating.
Install the filter horizontally and with the filter
holder facing downwards in order to facilitate
the depositing of impurities at the bottom.
In order to function properly, the solenoid valve
needs a difference of pressure between the
entrance and exit of water of at least 0.3 bar.
This is ensured if the solenoid valve is inserted
in the shower spout or near to it.
1) Filter
2) Solenoid valve
Fig. 11: Solenoid valve and filter