Helios EcoVent Verso KWL EC 45-160 Notice De Montage Et D'utilisation page 22

Masquer les pouces Voir aussi pour EcoVent Verso KWL EC 45-160:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Operating Instructions
EN
Unit with inner panel – KWL EC 45-160
1. Pull inner panel out (see Fig. 17).
2. Pull connection plug out and disconnect (see Fig. 18).
3. Pull the unit out using the removal tool (see Fig. 19).
4. Remove seal and tension band (see Fig. 20).
5. Open fan casing (see Fig. 20).
Unit
Removal tool
6. Remove heat accumulator from the fan casing (see Fig. 21).
Fan protection grille
7. Rinse heat accumulator under clear water and allow to dry completely.
8. Reassemble the unit in reverse order.
Fig .17
Pull inner
Disconnect
panel out
connection plug
Fig .19
Heat accumulator
9
Fig .18
Fig .20
Tension band
Seal
Fig .21
Insect protection grille

Publicité

Table des Matières
loading

Table des Matières