Error messages and error clearance
Message/symptom
Display: „- - -
No display function display OFF
OFF
Channel cannot be switched on
WXD 2:
No vacuum at desoldering tool
WXD 2:
Insufficient vacuum at desolde-
ring tool
WXA 2:
Hot air tool has no air
rear port
Does not function with Zero
Smog/ WHP/PC/ WFV 60A
front port
Does not function with Zero
Smog/ WHP/PC/ WFV 60A
Possible cause
Tool has not been detected
Tool defective
No mains supply voltage
Overload cut-out
Channel switched off
Vacuum not connected
Desoldering nozzle clogged
Compressed air not or
incorrectly connected
Filter cartridge on desoldering
tool full
Main filter on soldering station
full
Air hose not connected
Compressed air not or
incorrectly connected
Robot output set to Stop/Go
Footswitch is on
Remedial measures
Check connection of tool to
device
Check connected tool
Turn on mains power switch
Check mains supply voltage
Check device fuse
Only one soldering iron can be
operated.
Connect vacuum hose to
vacuum connection
Service desoldering nozzle
using cleaning tool
Connect compressed air to
compressed air connection or
check
Change filter cartridge on
desoldering tool full
Change the main filter element
on the soldering station
Connect compressed air to
compressed air hose or check
Connect air hose of tool to
WXA 2 or check
Deactivate Stop & Go function;
Or use front RS 232 port
Deactivate Footswitch; Or use
rear RS 232 port
39