Télécharger Imprimer la page

Beko Bari 91B Notice D'utilisation page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
appliances generated by other than an electrical source.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with a
smaller diameter is used, the efficiency of the product may
be reduced and its operation may become noisier.
Attention!
• Before proceeding with the installation, to be able to move the
hood more easily, complete the following operations:
1. Remove the anti-grease filterl by pulling the handle, as
shown in figure 2 - phase 1.
2. If the product is equipped with activated charcoal filters (B-
C), remove them as shown in figure 2 - phase 2B or 2C.
3. Unhook the small cupola M as shown in figure 2 - phase 4.
• Fixing to the wall (Fig.3):
- Mark the position of the lower side of the hood on the wall
figure 3 - phase 1(taking into account the minimum distance
required from the hob).
- Position the fixing template on the wall, making sure that
the line coincides with the line previously made on the wall,
as described in the preceding section.
- Mark and drill fixing holes figure 3 - phase 2.
- Fasten the 4 anchors and the 2 screws A-B without fully
tightening them figure 3 - phase 2.
- Position the appliance on the wall and permanently secure it
by pulling the 2 screws B figure 3 - phase 3-4 and the 2 locking
screws B figure 3 - phase 5.
- When carrying out the fixing operations, use only screws
and screw anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard etc.).
- If the screws and screw anchors are supplied with the ap-
pliance, make sure that they are suited to the type of wall to
which the hood must be fixed.
• Fixing to the wall OPTIONAL ACCESSORIES (Fig.4):
This hood model can have optional levelling brackets which
can be requested from your dealer.
- Mark the position of the lower side of the hood on the wall
figure 3 - phase 1(taking into account the minimum distance
required from the hob).
- Position the fixing template on the wall, making sure that
the line coincides with the line previously made on the wall,
as described in the preceding section.
- Mark and drill fixing holes figure 3 - phase 2.
- Take the two levelling brackets C and fix them to the hood
support with the screws D as indicated in figure 4 - step 1. Do
not tighten the 2 levelling screws D.
- Take the appliance and hang it on the two screws B figure
4 - step 2.
- Align the appliance horizontally by adjusting the two levelling
screws D figure 4 - step 3.
- When you have finished the adjustment, tighten the 2 screws
B figure 4 - step 4 and mount the hood on the wall permanently
using the two safety screws B figure 4 - step 5.
- When carrying out the fixing operations, use only screws
and screw anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard etc.).
If the screws and screw anchors are supplied with the appli-
ance, make sure that they are suited to the type of wall to
which the hood must be fixed.
- Filtering version
- Unhook the small cupola M and remove the grille E (Fig. 5).
- Pass the power supply cable through the slots of the small
cupola M as shown in Fig. 6.
- Take the fairlead H and position it between the power sup-
ply cable and the slot.
- Fasten the small cupola M and the grille E making sure that
is it perfectly hooked on to the fastening pins G. (Fig. 6).
The filters must be applied to the suction unit positioned inside
the hood. They must be centred by turning them 90 degrees
until the stop catch is tripped (Fig.10B).
• Optional accessories
This model may have decorative ducts as optional accessories
- ask your retailer for information.
Before installing decorative flues it is necessary to remove the
small cupola and loosen the 4 screws B that lock the fastening
pins G as shown in Fig.7.
• Installation of models with decorative ducts - extrac-
tor hood
Make sure the electrical power supply is within the measure-
ments of the decorative connector.
Connect flange F to the air exhaust hole using flexible hose
L (Fig.7).
Adjust the width of the support bracket of the top connector
(Fig. 8). Then fix it to the ceiling so that it is on the same axis
as the hood using screws A and observing the distance from
the ceiling shown in (Fig. 8). Slide the top connector inside
the lower duct and place this on the body (Fig. 9).
Pull out the top duct as far as the bracket and secure it using
screws B (Fig. 8).
To transform the hood from a ducting version into a filtering
version, ask your dealer for the charcoal filters and follow the
installation instructions.
• Filter hood:
Please note:
- In order to transform the hood from EXTRACTOR HOOD
into FILTER HOOD the active carbon filters must be ordered
at your distributor as accessory.
We have 3 different types of Kit, one with non-regenerable
active carbon filters (Fig.10B) and the other one with regen-
erable active charcoal filters (washable) (Fig.10C - Fig.10D).
- Depending on the model one owns, the CIRCULAR active
carbon filters must be applied to the suction unit located
inside the hood, centring them and rotating them by 90
degrees until they snap into place (Fig.10B), to replace them
perform the operation in reverse order.
- For WASHABLE regenerable activated carbon filters
(Fig.10C), follow the assembly instructions contained in
the KIT.
- For the WASHABLE CIRCULAR regenerable active carbon
filters (Fig.10D), remove the pad and follow the instructions in
the USE AND MAINTENANCE paragraph, "regenerable active
carbon filters".
USE AND MAINTENANCE
• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air. The effective
performance of the cooker hood depends on constant main-
tenance; the anti-grease filter and the active carbon filter both
require special attention.
• The anti-grease filter is responsible retaining the grease
particles suspended in the air, therefore it is subject to clogging
with variable frequency according to the use of the appliance.
- 23 -

Publicité

loading